5.2.2. Removal and installation of electric motors of the drive of gates
Electric motors of the drive of air gates of the conditioner of air
|
1 — Em of the drive of the gate of the left air duct of an obduv of glass 2 — Em of the drive of the left blocking gate 3 — Em of the drive of the gate of the right air duct of an obduv of glass 4 — Em of the regulator of the gate of the coal filter 5 — Em of the fan 6 — Em of the drive of the gate of the switch of the modes of circulation |
7 — Em of the drive of the right blocking gate 8 — Em of the drive of the gate of an air duct of the right foot well 9 — Em of the drive of the left gate of supply of fresh air 10 — Em of the drive of the right gate of supply of fresh air 11 — Em of the drive of the gate of an air duct of the left foot well |
Conditioner model without comfort automatic equipment
Ventilating gates move by means of electric motors. Electric motors are fixed on the heater/conditioner block. For access to electric motors it is necessary to remove various covers.
Removal
|
|
1. Disconnect a negative cable (-) of the rechargeable battery at the switched-off ignition. It is previously necessary to remove a box of the filter of air of salon.
|
2. Gate of fresh air / circulation: Uncover under a ware box, address appropriate section. 3. Air mixing gate right: Uncover under a ware box, address appropriate section. 4. Air mixing gate left: Uncover under the dashboard from the driver, address appropriate section.
|
|
Gate of the region of an arrangement of legs
|
1. Uncover under the dashboard from the driver, address appropriate section. 2. Remove the lower part of the dashboard from the driver, address appropriate section. 3. Remove the radio receiver and a pocket under the radio receiver, address the Section Removal and installation of the radio receiver. 4. Take out the damping material. |
|
Ventilating gates
|
1. Remove the block of a heater and the conditioner, address appropriate section. 2. Remove the radio receiver and a pocket under the radio receiver, address the Section Removal and installation of the radio receiver. 3. Take out the damping material.
|
4. Turn out 3 screws (arrows on an illustration) and remove an electric motor (1).
|
5. Disunite the socket (2) electric motors. |
|
Installation
|
1. Installation is carried out in the sequence, the return to removal. 2. Attach a cable of mass of the rechargeable battery at the switched-off ignition. Install into place a box of the filter of air of salon. If it is necessary, enter a code of the radio receiver and determine time on hours.
|
After installation it is necessary to adjust electric motors of the drive of ventilating gates on the control unit. On HUNDRED for this purpose there is a special diagnostic unit. |
|
|